Project Overview
This project is designed to maintain continuous supply to an AC load by selecting among four available sources: solar, PHCN, generator and inverter.
The PIC16F876A monitors source-availability inputs, applies the documented priority arrangement and drives the appropriate relay. An LCD identifies the source currently supplying the load.
How the System Works
- The four source-status inputs indicate which supplies are available.
- The PIC16F876A evaluates the source conditions and priority.
- The controller drives the relay path for the highest-priority available source.
- If that source becomes unavailable, the next available source is selected.
- The LCD displays the source currently connected to the load.
System Architecture
◆Solar / PHCN / Generator / InverterSource inputs
→
◆PIC16F876APriority logic
→
◆Relay DriverSource switching
→
◆AC LoadDemonstration load
→
◆LCDActive-source display
Project Gallery
Actual project photographs and technical images.
Actual project photographs and circuit diagram